Cookie Img
Back to top
Home » Products » SMPS » Single Output Switching Power Supply

Single Output Switching Power Supply

Single Output Switching Power Supply
Single Output Switching Power Supply
Product Code : S-50
Product Description

Product Description:

S-50 Single output switching power supply 
Low price and high reliability 
105 output capacitor 
AC input power suitable for the world 
High efficiency and low operation temperature 
Soft-start current can reduce the AC input impact effecticly 
With Short-circuit and overload protection 
Compact size,light weight 
100% full-load burning test 
Installed with EMI filter,minimum wave

Technique parameter:

 Model
Specification

S-50-5

S-50-12

S-50-15

S-50-24

DC output voltage

5V

12V

15V

24V

Output voltage errorNote2

±2%

±1%

±1%

±1%

Rated output current

10A

4.2A

3.4A

2.1A

Output current rage

0-10A

0-4.2A

0-3.4A

0-2.1A

Wave and noise(Note 3

75mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note 4

±0.5%

±0.5%

±0.5%

±0.5%

Load stability (Note 5

±1%

±0.5%

±0.5%

±0.5%

DC output power

50W

50.4W

51W

50.4W

Efficiency

71%

78%

78%

78%

Adjustable range for DC voltage

+10,-5%

+10%

+10%

+10%

AC input voltage range

85-132VAC/170-264VACSelected by switch47-63Hz240-370VDC

Input current

1.3A/115V 0.65A/230A

AC INnrush current

Cold-start current18A/115V 36A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%-150%Type:Fold back:current limiting reset:auto recovery

Over-voltage protection

…………

High-temperature protection

…………

Temperature coefficient

±0.03%/℃0-50℃

Setup rise hold up time

200ms,100ms,30ms

Vibration

10-500HZ,2G 10min,/1cyclePeriod for60minEach axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10℃~+60℃Refer to output derating curve),20%~90%RH

Store temperature and humidity

-20℃~+85℃10%~95%RH

Overall dimension

157×97×38mm

Weight

0.5Kgs

Safety standards

Meet UL 1012 requirement(Not apply for the mark)

EMC standards

…………

Note
1.The testing condition for the paramenter above is :230VAC input,rated load,25℃70% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.