Product Code : S-40
Product Description

Product Description:

S-40 Single output switching power supply 
Low price and high reliability 
105 output capacitor 
AC input power suitable for the world 
High efficiency and low operation temperature 
Soft-start current can reduce the AC input impact effecticly 
With Short-circuit and overload protection 
Compact size,light weight 
100% full-load burning test 
Installed with EMI filter,minimum wave

Technique parameter:

Model

S-40-5

S-40-12

S-40-15

S-40-24

Specification

DC output voltage

5V

12V

15V

24V

Output voltage errorNote2

±2%

±1%

±1%

±1%

Rated output current

8A

3.5A

2.8A

1.8A

Output current rage

0-8A

0-3.5A

0-2.8A

0-1.8A

Wave and noise(Note 3

75mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note 4

±0.5%

±0.5%

±0.5%

±0.5%

Load stability (Note 5

±1%

±0.5%

±0.5%

±0.5%

DC output power

40W

42W

42W

43W

Efficiency

72%

76%

77%

78%

Adjustable range for DC voltage

+10,-5%

+10%

+10%

+10%

AC input voltage range

85-264VAC 47-63Hz120-370VDC

Input current

1.2A/115V 0.6A/230V

AC INnrush current

Cold-start current 30A/115V 60A/230V

Leakage current

<1mA/240VAC

Overload protection

105%~150% Type:pulsing hiccp shutdown Reset:auto recovery

Over-voltage protection

115%~135%

High-temperature protection

…………

Temperature coefficient

±0.3%/(0~50%)

Setup rise hold up time

…………

Vibration

10-500HZ,2G 10min,/1cyclePeriod for 60minEach axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve),20%~90%RH

Store temperature and humidity

-20~+85,10%~95%RH

Overall dimension

129×98×38mm

Weight

0.45Kgs

Safety standards

UL1012 TUV6050(IEC,UL1950)Approved

EMC standards

CISPR22(55022),IEC801-2,3,4,IEC555-2 Verification

Note
1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.
6.C236 must be knocked down.