Product Code : FS-100W
Product Description

Product Description:

FS-100W LED rainproof power supply 
       ·170264VAC AC input 
       ·Small volumelow weighthigh efficiency 
       ·Protectionsshort circuit/over load 
       ·cooling by free air convection 
       ·Fully encapsulated with IP44 level 
       ·100% full load burn-in test 
       ·2 Year warranty

Technique parameter:

Model

FS-100-12

FS-100-15

FS-100-24

FS-100-36

FS-100-48

output

DC voltage

12V

15V

24V

36V

48V

Voltage tolerance

±1%

±1%

±1%

±1%

±1%

Rated current

8.5A

6.7A

4.2A

2.8

2

Current range

0~8.5A

0~6.7A

0~4.2A

0~2.8A

0~2A

Rated power

102W

100.5W

100.8W

100.8W

96W

Ripple&noise

150mvp-p

150mvp-p

150mvp-p

200mvp-p

200mvp-p

DC voltage ADJ.range

±10%

±10%

±10%

±10%

±10%

input

Voltage range

170~264VAC255~373VDC

frequency

47~63HZ

AC current

1.2A/230VAC

efficiency

82%

82%

84%

85%

86%

Inrush current

Cold start current 45A/230VAC

Leakage current

< 3.5mA/240VAC

protection

overload

Rated output power115%~150% start over load protection

protection typehiccup modeauto-recovery after fault condition is removed

over voltage

15.6~17.8V

18.6~20.8V

30.6~33.2V

42.6~44.2V

54.8~56.6V

protection typehiccup modeauto-recovery after fault condition is removed

environment

Working temp,humidity

-10~+6020%~90%RH

Storage temp,humidity

-20~+8510%~95%RH non-condensing

Withstand vibration

10~500HZ2G 10min/1cycleperiod for 60 minuteseach axes

safety

Withstand voltage

I/P-O/P1.5KVAC I/P-FG1.5KVAC O/P-FG0.5KVAC

Isolated resistance

I/P-O/P,I/P-FG,O/P-FG100M ohms/500VDC

Fit standard

Safety standard

Fit UL1012 IP44

EMC standard

符合EN55022CLASSA

others

Dimension

206*125*50mm (L*W*H)

Weight/packing

0.87kg/20pcs/18.5kg/0.039m3;/1.36CUFT

note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

X