Cookie Img
Back to top
Home » Products » SMPS » Din Rail Switching Power Supply

Din Rail Switching Power Supply

Din Rail Switching Power Supply
Din Rail Switching Power Supply
Send Inquiry
Product Code : DR-45
Product Description

Product Description:

Universal AC input/ full range 
Protections: Short circuit/ Over load/ Over voltage/ Over temperature 
Cooling by free air convection 
Can be installed on DIN rail TS-35/7.5 or 15 
LED indicator for power on 
100% full load burn-in test 
Fixed switching frequency at 100KHz 
3 years warranty 
Dimensions: 93*78*67mm (L*W*H)

Technique parameter:

Model

DR-45-5

DR-45-12

DR-45-24

 

 

 

output

DC voltage

5V

12V

24V

Voltage tolerance

±2%

±1%

±1%

Rated current

5A

3.5A

2A

Current range

0~5A

0~3.5A

0~2A

Rated power

25W

42W

48W

Ripple&noise

80mvp-p

100mvp-p

150mvp-p

DCvoltage ADJ.range

-9%~+10%

±10%

±10%

 

 

input

Voltage range

90~264VAC127~373VDC

frequency

47~63HZ

AC current

1.0A/110VAC0.55A/220VAC

efficiency

75%

81%

83%

Inrush current

Cold start current 20A/115VAC40A/230VAC

Leakage current

< 1mA/240VAC

 

protection

Over load

Rated output power105%~150% start over load protection

protection typehiccup modeauto-recovery after fault condition is removed

over voltage

6.8~8.2V

15.6~17.8V

30.6~33.2V

protection type:cut off output voltage,diode clamp

environment

Working temp,humidity

-20~+6020%~90%RH

Storagetemp,humidity

-40~+8510%~95%RH non-condensing

Withstand vibration

10~500HZ2G 10min/1cycleperiod for 60 minuteseach axes

safety

Withstand voltage

I/P-O/P3KVAC I/P-FG1.5KVAC O/P-FG0.5KVAC

Isolated resistance

I/P-O/P,I/P-FG,O/P-FG100M ohms/500VDC

Fitstandard

Safety standard

Fit UL1012

EMC standard

EN55022CLASSA

others

Dimension

78*93*56mm (L*W*H)

Weight/packing

0.3kg/48pcs/15.4kg/0.03m3;/1.07CUFT

note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

 

X