Cookie Img
Back to top
Home » Products » SMPS » Daul Output Switching Power Supply

Daul Output Switching Power Supply

Daul Output Switching Power Supply
Daul Output Switching Power Supply
Product Code : D-50
Product Description

Product Description:

D-50 Daul output switching power supply 
Low price and high reliability 
105 output capacitor 
AC input power suitable for the world 
High efficiency and low operation temperature 
Soft-start current can reduce the AC input impact effecticly 
With Short-circuit and overload protection 
Compact size,light weight 
100% full-load burning test 
Installed with EMI filter,minimum wave

Technique parameter:

                  Model
Specification

D-50A

D-50B

CH1

CH2

CH1

CH2

DC output voltage

5V

12V

5V

24V

Output voltage errorNote2

±2%

+5,-8%

±2%

±8%

Rated output current

6A

2A

6A

1A

Output current rage

1-6A

0.3-2A

1-6A

0.2-1A

Wave and noise(Note 3

50mVp-p

100mVp-p

50mVp-p

100mVp-p

Inlet stability(Note 4

±0.5%

±1%

±0.5%

±1%

Load stablity (Note 5

±0.5%

±5%

±0.5%

±8%

DC output power

54W

54W

Efficiency

72%

73%

Adjustable range for DC voltage

CH1;+10,-5%

CH1:+10,-5%

AC input voltage range

85-132VAC/170-264VACSelected by switch47-63Hz240-370VDC

Input current

1.3A/115V 0.65A/230A

AC INnrush current

Cold-start current30A/115V 60A/230V

Leakage current

<0.5mA/240VAC

Overload proctection

105%-150%Type:Foldback:current limiting reset:auto recovery

Over-voltage protection

…………

High-temperature protection

…………

Temperature coefficient

±0.03%/℃(0-50℃)

Setup rise hold up time

200ms,50ms,30ms

Vibration

10-500Hz,2G 10min,/1cyclePeriod for60minEach axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60℃(Refer to output derating curve),20%~90%RH

Store temperature and humidity

-20~+85℃。10%~95%RH

Overall dimension

159×97×38mm

Weight

0.52Kgs

Safety standards

Meet UL 1012 requirement (Not apply for the mark)

EMC standards

…………

Note
1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.
6.Total output can be maximum Current,total load can not exceed the maximum output power