Product Description

Product Description:

MS-120 compact single switching power supply 
·170264VAC AC input         
·Small volumelow weighthigh efficiency 
·Protectionsshort circuit/over load 
·cooling by free air convection 
·LED indicator for power on 
·100% full load burn-in test 
.2 Year warranty

Technique parameter:

Model

MS-120-12

MS-120-15

MS-120-24

MS-120-36

MS-120-48

output

DC voltage

12V

15V

24V

36V

48V

Voltage tolerance

±1%

±1%

±1%

±1%

±1%

Rated current

10A

8A

5A

3.3A

2.5A

Current range

0~10A

0~8A

0~5A

0~3.3A

0~2A

Rated power

120W

120W

120W

118.8W

120W

Ripple&noise

100mvp-p

120mvp-p

150mvp-p

150mvp-p

180mvp-p

DC voltage ADJ.range

±10%

±10%

±10%

±10%

±10%

input

Voltage range

90~132VAC/180~264VAC(selected by switch)254~373VDC

frequency

47~63HZ

AC current

2.8A/115VAC1.4A/230VAC

efficiency

82%

83%

85%

85%

86%

Inrush current

Cold start current 18A/115VAC36A/230VAC

Leakage current

< 3.5mA/240VAC

protection

overload

Rated output power115%~150% start over load protection

protection typehiccup modeauto-recovery after fault condition is removed

Over voltage

15.6~17.8V

18.6~20.8V

30.6~33.2V

42.6~44.2V

54.8~56.6V

protection typehiccup modeauto-recovery after fault condition is removed

-----

-----

-----

environment

Working temp,humidity

-10~+6020%~90%RH

Storage temp,humidity

-20~+8510%~95%RH non-condensing

Withstand vibration

10~500HZ2G 10min/1cycleperiod for 60 minuteseach axes

safety

Withstand voltage

I/P-O/P1.5KVAC I/P-FG1.5KVAC O/P-FG0.5KVAC

Isolated resistance

I/P-O/P,I/P-FG,O/P-FG100M ohms/500VDC

Fit standard

Safety standard

Fit UL1012

EMC standard

EN55022CLASSA

others

Dimension

159*97*38mm (L*W*H)

Weight/packing

0.48kg/45pcs/22.5kg/0.041 m3;/1.45CUFT

note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.